Data Group Element Description FMS Item String Native Data Group Native Data Group Element
cfg001 Meter Type eFMS_CFG_METER_TYPE Set in Device Editor N/A
cfg002 Primary Calc Method eFMS_CFG_CALC_METHOD_PRIMARY Station Parameters CalcStan
cfg003 Compressibility Calc Method eFMS_CFG_CALC_METHOD_FPV Station Parameters CompCalc
cfg007 Meter ID eFMS_CFG_METER_ID (Orifice or Turbine) Meter Run Configuration Tag
cfg008 Meter Description eFMS_CFG_METER_DESC (Orifice or Turbine) Meter Run Configuration PntDesc
cfg009 Contract Hour eFMS_CFG_CONTRACT_HOUR Liquid Preferences for a liquid meter with firmware v1.03 or later;
History Segment 0 Configuration for a liquid meter with firmware version less than v1.03;
History Segment Configuration for all other ROCPlus models, meter types, and firmware combinations.
CntcfH for a liquid meter with firmware v1.3 or later.

ContHour for all other ROCPlus models, meter types, and firmware combinations.
cfg010 Base Pressure eFMS_CFG_BASE_PRESSURE Station Parameters BCPress
cfg011 Base Temperature eFMS_CFG_BASE_TEMPERATURE Station Parameters BCTemp
cfg012 Meter Tube Inside Diameter eFMS_CFG_METER_TUBE_INSIDE_DIAMETER Orifice Meter Run Configuration PipeDiam
cfg013 Meter Tube Reference Temperature eFMS_CFG_METER_TUBE_REF_TEMP Orifice Meter Run Configuration PipeTemp
cfg014 Meter Tube Material eFMS_CFG_METER_TUBE_MATERIAL Orifice Meter Run Configuration PipeMat
cfg015 Orifice Plate Bore Size eFMS_CFG_ORIFICE_PLATE_BORE_SIZE Orifice Meter Run Configuration OrfDiam
cfg016 Orifice Plate Reference Temperature eFMS_CFG_ORIFICE_PLATE_REF_TEMP Orifice Meter Run Configuration OrfTemp
cfg017 Orifice Plate Material eFMS_CFG_ORIFICE_PLATE_MATERIAL Orifice Meter Run Configuration OrfMat
cfg021 DP Taps Type eFMS_CFG_DP_TAPS_TYPE Orifice Only
Fixed
Orifice Only
Fixed
cfg022 SP Tap Location eFMS_CFG_SP_TAP_LOCATION Orifice Meter Run Configuration SPTap
cfg023 SP Sensor Type eFMS_CFG_SP_SENSOR_TYPE (Orifice or Turbine) Meter Run Configuration SPUnits
cfg024 Atmospheric Pressure eFMS_CFG_ATMOSPHERIC_PRESSURE Station Parameters AP
cfg025 Meter factor eFMS_CFG_METER_FACTOR (Orifice or Turbine) Meter Run Configuration UserCor (Orifice)
UserCF (Turbine)
cfg026 K factor eFMS_CFG_GAS_K_FACTOR_VOLUME
(previously eFMS_CFG_K_FACTOR)
Linear Meter Run Configuration KFactor
cfg030 Methane eFMS_CFG_METHANE Station Parameters CH4
cfg031 Ethane eFMS_CFG_ETHANE Station Parameters C2H6
cfg032 Propane eFMS_CFG_PROPANE Station Parameters C3H8
cfg033 Isobutane eFMS_CFG_ISOBUTANE Station Parameters C4H10i
cfg034 n-Butane eFMS_CFG_N_BUTANE Station Parameters C4H10n
cfg035 Isopentane eFMS_CFG_ISOPENTANE Station Parameters C5H12i
cfg036 n-Pentane eFMS_CFG_N_PENTANE Station Parameters C5H12n
cfg038 n-Hexane eFMS_CFG_N_HEXANE Station Parameters C6H14
cfg039 n-Heptane eFMS_CFG_N_HEPTANE Station Parameters C7H16
cfg040 n-Octane eFMS_CFG_N_OCTANE Station Parameters C8H18
cfg041 n-Nonane eFMS_CFG_N_NONANE Station Parameters C9H20
cfg042 n-Decane eFMS_CFG_N_DECANE Station Parameters C10H22
cfg043 Nitrogen eFMS_CFG_NITROGEN Station Parameters N2
cfg044 Carbon Dioxide eFMS_CFG_CARBON_DIOXIDE Station Parameters CO2
cfg045 Water eFMS_CFG_WATER Station Parameters H2O
cfg046 Hydrogen Sulfide eFMS_CFG_HYDROGEN_SULFIDE Station Parameters H2S
cfg047 Hydrogen eFMS_CFG_HYDROGEN Station Parameters H2
cfg048 Carbon Monoxide eFMS_CFG_CARBON_MONOXIDE Station Parameters CO
cfg049 Oxygen eFMS_CFG_OXYGEN Station Parameters O2
cfg050 Helium eFMS_CFG_HELIUM Station Parameters He
cfg051 Argon eFMS_CFG_ARGON Station Parameters Ar
cfg055 Heating Value - Volume eFMS_CFG_HEATING_VALUE_VOLUME Station Parameters HeatVal
cfg057 Heating Value Basis eFMS_CFG_HEATING_VALUE_BASIS Station Parameters HeatVT
cfg058 Relative Density eFMS_CFG_RELATIVE_DENSITY Station Parameters SpecGr
cfg061 Viscosity eFMS_CFG_VISCOSITY Orifice Meter Run Configuration Viscos
cfg082 Isentropic Exponent eFMS_CFG_ISENTROPIC_EXPONENT Orifice Meter Run Configuration HeatRat
cfg086 Elevation eFMS_CFG_ELEVATION Station Parameters Elevat
cfg089 Low Flow Cutoff (DP) eFMS_CFG_LOW_FLOW_CUTOFF_DP Orifice Meter Run Configuration LowDPC
cfg90 Low Flow Cutoff Flow Rate eFMS_CFG_LOW_FLOW_CUTOFF_FLOW_RATE Linear Meter Run Configuration LFCut
cfg091 No Flow Time eFMS_CFG_LOW_FLOW_CUTOFF_PULSE_INTERVAL Linear Meter Run Configuration NoFloTm
cfg106 DP Alarm Low eFMS_CFG_DP_ALARM_LOW Unexposed data group Unexposed data group element
cfg107 DP Alarm High eFMS_CFG_DP_ALARM_HIGH Unexposed data group Unexposed data group element
cfg108 SP Alarm Low eFMS_CFG_SP_ALARM_LOW Unexposed data group Unexposed data group element
cfg109 SP Alarm High eFMS_CFG_SP_ALARM_HIGH Unexposed data group Unexposed data group element
cfg110 Temp Alarm Low eFMS_CFG_TEMP_ALARM_LOW Unexposed data group Unexposed data group element
cfg111 Temp Alarm High eFMS_CFG_TEMP_ALARM_HIGH Unexposed data group Unexposed data group element
cfg115 DP Calibrate Low eFMS_CFG_DP_CALIBRATE_LOW Unexposed data group Unexposed data group element
cfg116 DP Calibrate High eFMS_CFG_DP_CALIBRATE_HIGH Unexposed data group Unexposed data group element
cfg117 SP Calibrate Low eFMS_CFG_SP_CALIBRATE_LOW Unexposed data group Unexposed data group element
cfg118 SP Calibrate High eFMS_CFG_SP_CALIBRATE_HIGH Unexposed data group Unexposed data group element
cfg119 Temp Calibrate Low eFMS_CFG_TEMP_CALIBRATE_LOW Unexposed data group Unexposed data group element
cfg120 Temp Calibrate High eFMS_CFG_TEMP_CALIBRATE_HIGH Unexposed data group Unexposed data group element
cfg122 Use Coriolis Pressure Effect eFMS_CFG_USE_CORIOLIS_PRESSURE_EFFECT Linear Meter Run Configuration MassComp
cfg125 Use Live K Factor eFMS_CFG_USE_LIVE_K_FACTOR Linear Meter Run Configuration Frqncy
cfg126 Use Live Meter Factor eFMS_CFG_USE_LIVE_METER_FACTOR Fixed Fixed
cfg510 Latitude eFMS_CFG_LATITUDE Station Parameters Latitude
cfg513 Sample Type eFMS_CFG_SAMPLE_TYPE Fixed Fixed
cfg604 Shrink Factor eFMS_CFG_SHRINK_FACTOR Liquid Meter Run Configuration ShrnkgF